OG_STD-302S-429M_v11e 11 Circuit Design, Inc.
OPERATION GUIDE
PLL IC CONTROL
PLL IC control
OSCin
OSCout
Vp
VCC
Do
GND
Xf in
Fin
R
P
STD-302
Control pin name
ZC
PS
LE
Data
2kohm
MB15E03SL
Reference Oscillator
LPF
Voltage Controled
Oscillator
VCO
PLL
CLK
DATA
LE
LD
LD/f out
+2.8v
#:Control v oltage = +2.8v
21.25MHz
up to 1200MHz
Figure 1
CLK
2kohm
2kohm
2kohm
STD-302S is equipped with an internal PLL frequency synthesizer as shown in Figure 1. The operation of the PLL
circuit enables the VCO to oscillate at a stable frequency. Transmission frequency is set externally by the
controlling IC. STD-302S has control terminals (CLK, LE, DATA) for the PLL IC and the setting data is sent to the
internal register serially via the data line. Also STD-302S has a Lock Detect (LD) terminal that shows the lock
status of the frequency. These signal lines are connected directly to the PLL IC through a 2 kΩ resistor.
The interface voltage of STD-302S is 2.8 V, so the control voltage must be the same.
STD-302S comes equipped with a Fujitsu MB15E03SL PLL IC. Please refer to the manual of the PLL IC.
The following is a supplementary description related to operation with STD-302S. In this description, the same
names and terminology as in the PLL IC manual are used, so please read the manual beforehand.